Basic Introduction
In this project, to solve this problem, we launched an electrical cabinet with integrated active filter.
This Product combines advanced power electronics technology and intelligent control system,
which can effectively filter harmonics, compensate reactive power, and improve three-phase imbalance,
ensuring the stability and reliability of the power distribution system.
Working Principle
The active filter cabinet is based on active power filter (APF) technology.
By real-time detection of harmonic components in load current,
it dynamically injects reverse compensation current to achieve harmonic suppression,
reactive power compensation and three-phase imbalance control.
Compared with traditional passive filters.
![]() |
![]() |
![]() |
Product Features
High-efficiency filtering: It can dynamically filter 2~50 harmonics, and the filtering accuracy is as high as 97% or more.
Fast response: The response time to load fluctuations is less than 1ms, and it can quickly adapt to system changes.
Intelligent control: It adopts DSP full digital control, with functions such as automatic detection, reactive power compensation, and resonance suppression.
Modular design: It supports multiple units in parallel operation and can flexibly expand capacity according to demand.
Energy saving and protection: improve system power factor, reduce line loss, and have multiple protection functions such as overcurrent and overvoltage.
Technical parameters
Rated working voltage: | 380V/220V, 50Hz |
Rated harmonic compensation capacity: | 50A/100A/150A/200A |
Power consumption of the whole machine | less than 3% of the capacity |
Insulation voltage | 3000V AC, 2500V DC |
Advantages
Active response: no need to rely on system impedance, can accurately track harmonic frequency changes;
Intelligent control: integrated digital signal processing (DSP) algorithm, adaptive adjustment compensation strategy;
Full frequency band coverage: effectively filter out 2-50 harmonics, compatible with linear and nonlinear load scenarios.
Core issues solved for customers
Power quality management
Eliminate equipment overheating, malfunction and cable aging caused by harmonics;
Avoid power adjustment electricity fee fines due to substandard power factor.
Improved system stability
Suppress voltage fluctuations and flickers to ensure stable operation of precision equipment (such as CNC machine tools, medical CT);
Solve the problem of increased transformer losses caused by three-phase imbalance.
Long-term cost optimization
Extend the life of electrical equipment (such as motors, UPS), and reduce unplanned downtime losses;
Reduce grid electricity charges through reactive power compensation, and the investment recovery period is ≤2 years.
Application scenarios
The electrical cabinet is suitable for a variety of industries, including industry, commerce, data centers, medical institutions, airports and ports, etc.
It can effectively solve the problem of harmonic pollution, extend equipment life, reduce maintenance costs,
and improve the reliability and stability of the power supply system.